Frederik Gladhorn
919139d9e8
Add logging
...
Instead of using print, let's use Python's logging framework. That
allows switching verbosity easily and filtering out unwanted messages.
Some of the setup code is inspired by what Home Assistant does.
2020-01-31 22:01:17 +01:00
David
a62572e599
Merge remote-tracking branch 'upstream/master'
2020-01-22 12:19:26 -05:00
David
7b7f1e76f6
change power usage names and added units
2020-01-22 12:17:36 -05:00
Frederik Gladhorn
f44aa91b24
Make flake8 happy
...
For some reason I don't get the same error on my local machine, I guess
it's different flake8 versions.
2020-01-22 15:32:02 +01:00
David
4122d7d188
add power readings to ac_config
2020-01-22 00:28:53 -05:00
Frederik Gladhorn
cc3d60f882
Error out when language or country are invalid
...
Many people seem to stumble over this (I did, specifying en_US instead
of en-US for example). I don't know of any valid inputs other than two
letter combinations, but three letters could be valid.
2020-01-13 13:28:10 +01:00
Frederik Gladhorn
6461596219
Use f-strings for command line options
...
These are more readable than the .format strings.
2020-01-13 13:05:26 +01:00
Adrian Sampson
26fd47471b
Merge pull request #67 from gladhorn/exec_bit
...
Make example.py executable
2020-01-11 11:54:32 -05:00
Adrian Sampson
c5fb01e7cc
Print error message to stderr ( #66 )
2020-01-11 11:43:48 -05:00
Adrian Sampson
a1cd9795c6
Wrap error message to 79 characters
2020-01-11 11:43:13 -05:00
Frederik Gladhorn
a727828064
Make example.py executable
...
This makes it easier to run the file on unix systems.
2020-01-09 22:00:42 +01:00
Frederik Gladhorn
ff8d0ba9e0
Print error on invalid command
2020-01-09 21:58:56 +01:00
Adrian Sampson
07b6a1ca21
Handle NotConnectedError in example
2019-11-28 09:34:51 -05:00
Adrian Sampson
b176cd26ee
Nice error when device can't be found
...
Inspired by #17 .
2019-06-20 13:17:02 -04:00
Adrian Sampson
8929123c8d
Add country and language flags to example ( #13 )
2019-06-16 14:51:20 -04:00
Adrian Sampson
0317c81bdf
Use argparse for example
2019-06-16 14:30:11 -04:00
nordron
4ad4946719
Revert changes
2018-09-12 00:17:56 +03:00
krocans
5a5e8bf47d
DeviceInfo decodes monitor status data
2018-08-12 10:33:27 +03:00
krocans
910e55d018
Decode binary monitoring status data
2018-08-12 10:16:23 +03:00
root
0ee80dd122
Fix monitor data printed twice on missing 'value'
2018-08-11 23:32:08 +03:00
Adrian Sampson
4cde35597a
Style fixes
2018-06-17 10:37:41 -04:00
bindismal
add21143d2
Accepted proposed changes
2018-06-17 23:50:33 +10:00
bindismal
3c59047d10
Added support for zone control for ducted HVAC that support zone control
...
Added support for reading / setting fan speed
2018-06-16 21:34:33 +10:00
Adrian Sampson
0a48345409
Get speaker volume setting
...
Still can't figure out how to *set* the light state.
2018-04-21 15:14:10 -04:00
Adrian Sampson
6d3e7b3fa6
Add method for reading light state
2018-04-21 14:59:53 -04:00
Adrian Sampson
597895b263
Expose AC config values I know of so far
2018-04-21 14:42:11 -04:00
Adrian Sampson
fe77d66e96
Show how to check device type
2018-04-03 10:45:58 -04:00
Adrian Sampson
c696489de2
Fetch device type
2018-04-03 10:40:38 -04:00
Adrian Sampson
86c63a92b5
Not all devices return JSON status data
2018-04-03 10:17:04 -04:00
Adrian Sampson
dd9ff96b39
Example to turn on/off a device
2018-02-18 11:40:31 -05:00
Adrian Sampson
7f7988effa
Refactor example commands
2018-02-18 11:38:24 -05:00
Adrian Sampson
c7173124cd
On/off status
2018-02-18 11:26:47 -05:00
Adrian Sampson
f8107ebc25
An enum for OpMode
2018-02-18 11:13:50 -05:00
Adrian Sampson
315dbd73e1
Example of higher-level monitoring
2018-02-18 11:00:27 -05:00
Adrian Sampson
9bf03ddb46
Used namedtuples for value info
2018-01-21 12:47:17 -05:00
Adrian Sampson
844d1c1bdb
Look up value descriptions
2018-01-21 12:39:36 -05:00
Adrian Sampson
947ea8a647
DeviceInfo abstraction
2018-01-21 12:12:10 -05:00
Adrian Sampson
01366af56a
Inline unnecessary helpers
2018-01-21 11:39:11 -05:00
Adrian Sampson
ebc9c5b679
Make load into a class method
2018-01-20 21:47:32 -05:00
Adrian Sampson
2ce09e9642
Move Client to main module
2018-01-20 21:43:02 -05:00
Adrian Sampson
f50c8d0221
Simplify retry loop
2018-01-20 21:39:37 -05:00
Adrian Sampson
b2bc017d99
Cache device list
2018-01-20 21:35:09 -05:00
Adrian Sampson
948d51b1b6
Try wrapping stuff up in a mutable client class
2018-01-20 21:33:44 -05:00
Adrian Sampson
b3315c60c8
Refresh session in example
2018-01-20 17:02:43 -05:00
Adrian Sampson
35a78281d6
Auth.from_url helper
2018-01-20 13:56:16 -05:00
Adrian Sampson
8fc2749a9b
Obtain refresh token from OAuth
2018-01-20 13:53:19 -05:00
Adrian Sampson
29eb1804c5
Run monitor loop indefinitely
2018-01-08 14:47:27 -08:00
Adrian Sampson
336b7ec956
Fix format of control call
2018-01-08 14:46:04 -08:00
Adrian Sampson
c9afb9035c
Start controlling settings
2018-01-08 14:39:50 -08:00
Adrian Sampson
244f4756c5
Pull out temperatures
2018-01-08 14:26:14 -08:00