#!/usr/bin/env python
|
|
|
|
# Based on Morningstar documentation here
|
|
# http://www.morningstarcorp.com/wp-content/uploads/2014/02/TSMPPT.APP_.Modbus.EN_.10.2.pdf
|
|
# and heavily modified version of the script here
|
|
# http://www.fieldlines.com/index.php?topic=147639.0
|
|
|
|
# This is modified for the non-MPPT tri-stars without built-in network monitoring. It has different indices and different available data.
|
|
|
|
import sys
|
|
import re
|
|
import time
|
|
counter = 0
|
|
|
|
script = sys.argv[0]
|
|
host = re.sub(r".*tristar_monitoring_",'',script)
|
|
|
|
if len(sys.argv) == 2:
|
|
if sys.argv[1] == "config":
|
|
# print "host_name %s" % host
|
|
print "graph_category power"
|
|
print "graph_title Solar Charge Controller Info"
|
|
print "graph_vlabel A bit of all (V, A, C)"
|
|
print "vPanel.label panel potential (V)"
|
|
print "vPanel.max 80"
|
|
print "vBattTerm.label battery potential at terminals (V)"
|
|
print "vBattTerm.max 32"
|
|
print "vBattTerm.warning 25:32"
|
|
print "vBattTerm.critical 24:33"
|
|
# print "vBattSense.label battery potential sensing (V)"
|
|
# print "vBattSense.max 32"
|
|
print "hsTemp.label heat sink temperature (C)"
|
|
print "hsTemp.max 120"
|
|
print "hsTemp.warning :60"
|
|
print "hsTemp.critical :80"
|
|
# print "battTemp.label battery temperature (C)"
|
|
# print "battTemp.max 120"
|
|
# print "battTemp.warning :80"
|
|
# print "battTemp.critical :100"
|
|
print "aPanel.label charge current (A)"
|
|
print "aPanel.max 20"
|
|
# print "aPanel.warning :15"
|
|
# print "aPanel.critical :19"
|
|
# print "aBatt.label battery current (A)"
|
|
# print "aBatt.max 20"
|
|
# print "aBatt.warning :15"
|
|
# print "aBatt.critical :19"
|
|
exit(0)
|
|
# import the server implementation
|
|
from pymodbus.client.sync import ModbusSerialClient as ModbusClient
|
|
|
|
# configure the client logging
|
|
import logging
|
|
logging.basicConfig()
|
|
log = logging.getLogger('./modbus.error')
|
|
log.setLevel(logging.ERROR)
|
|
|
|
client = ModbusClient(method='rtu',port='/dev/ttyUSB0', baudrate=9600, timeout=1)
|
|
client.connect()
|
|
log.debug(client)
|
|
|
|
# Define the State list
|
|
state = ['Start', 'Night Check', 'Disconnected', 'Night', 'Fault!', 'MPPT', 'Absorption', 'FloatCharge', 'Equalizing', 'Slave']
|
|
|
|
# read registers. Start at 0 for convenience
|
|
rr = client.read_holding_registers(0,37,1)
|
|
if rr == None:
|
|
client.close()
|
|
log.error("couldn't connect")
|
|
exit(1)
|
|
|
|
# for all indexes, subtract 1 from what's in the manual
|
|
#V_PU_hi = rr.registers[0]
|
|
#V_PU_lo = rr.registers[1]
|
|
#I_PU_hi = rr.registers[2]
|
|
#I_PU_lo = rr.registers[3]
|
|
|
|
#V_PU = float(V_PU_hi) + float(V_PU_lo)
|
|
#I_PU = float(I_PU_hi) + float(I_PU_lo)
|
|
|
|
v_scale = 96.667 * 2**(-15)
|
|
i_scale = 66.667 * 2**(-15)
|
|
#p_scale = V_PU * I_PU * 2**(-17)
|
|
array_scale = 139.15 * 2**(-15)
|
|
# battery sense voltage, filtered
|
|
battsV = rr.registers[8] * v_scale
|
|
#battsV = ( rr.registers[8] * 96.667 ) / 32768
|
|
#battsSensedV = rr.registers[26] * v_scale
|
|
battsI = rr.registers[12] * i_scale * 4.75
|
|
arrayV = rr.registers[10] * array_scale
|
|
arrayI = rr.registers[11] * i_scale
|
|
#statenum = rr.registers[50]
|
|
hsTemp = rr.registers[14]
|
|
#rtsTemp = rr.registers[36]
|
|
#outPower = rr.registers[58] * p_scale
|
|
#inPower = rr.registers[59] * p_scale
|
|
#minVb_daily = rr.registers[64] * v_scale
|
|
#maxVb_daily = rr.registers[65] * v_scale
|
|
#minTb_daily = rr.registers[71]
|
|
#maxTb_daily = rr.registers[72]
|
|
#dipswitches = bin(rr.registers[48])[::-1][:-2].zfill(8)
|
|
#led_state = rr.registers
|
|
print "vBattTerm.value %.2f" % battsV
|
|
#print "vBattSense.value %.2f" % battsSensedV
|
|
#print "aBatt.value %.2f" % battsI
|
|
#print "battery watts: %.2f" % (battsV*battsI)
|
|
print "vPanel.value %.2f" % arrayV
|
|
print "aPanel.value %.2f" % arrayI
|
|
#print "array watts: %.2f" % (arrayV*arrayI)
|
|
print "hsTemp.value %.2f" % hsTemp
|
|
#print "battTemp.value %.2f" % rtsTemp
|
|
#print "state: %s" % state[statenum]
|
|
#print "out power: %0.2f" % outPower
|
|
#print "in Power: %0.2f" % inPower
|
|
#print "min Vb daily: %0.2f" % minVb_daily
|
|
#print "max Vb daily: %0.2f" % maxVb_daily
|
|
#print "min Tb daily: %0.2f" % minTb_daily
|
|
#print "max Tb daily: %0.2f" % maxTb_daily
|
|
#print "dipswitches: %s" % dipswitches
|
|
#print "dipswitches: 12345678"
|
|
#print ""
|
|
client.close()
|