#!/bin/bash
|
||||
#!/usr/bin/env python
|
||||
|
||||
HOSTNAME=`echo ${BASH_SOURCE[0]} | sed -r 's/^.*tristar_monitoring_(.*)$/\1/'`
|
||||
#printf "host_name %s\n" ${HOSTNAME}
|
||||
# Based on Morningstar documentation here
|
||||
# http://www.morningstarcorp.com/wp-content/uploads/2014/02/TSMPPT.APP_.Modbus.EN_.10.2.pdf
|
||||
# and heavily modified version of the script here
|
||||
# http://www.fieldlines.com/index.php?topic=147639.0
|
||||
|
||||
case $1 in
|
||||
config)
|
||||
echo host_name ${HOSTNAME}
|
||||
echo graph_title Panel Voltage
|
||||
echo graph_vlabel voltage
|
||||
echo voltage.label V
|
||||
exit 0;;
|
||||
esac
|
||||
import sys
|
||||
import re
|
||||
import time
|
||||
counter = 0
|
||||
|
||||
printf "voltage.value "
|
||||
/usr/local/bin/read_registers.py "${HOSTNAME}" | grep 'array voltage' | sed -r "s/^array voltage: +(.*)/\1/"
|
||||
script = sys.argv[0]
|
||||
host = re.sub(r".*tristar_monitoring_",'',script)
|
||||
|
||||
if len(sys.argv) == 2:
|
||||
if sys.argv[1] == "config":
|
||||
print "host_name %s" % host
|
||||
print "graph_category power"
|
||||
print "graph_title Solar Charge Controller Info"
|
||||
print "graph_vlabel A bit of all (V, A, C)"
|
||||
print "vPanel.label panel potential (V)"
|
||||
print "vPanel.max 80"
|
||||
print "vBattTerm.label battery potential at terminals (V)"
|
||||
print "vBattTerm.max 32"
|
||||
print "vBattTerm.warning 25:32"
|
||||
print "vBattTerm.critical 24:33"
|
||||
print "vBattSense.label battery potential sensing (V)"
|
||||
print "vBattSense.max 32"
|
||||
print "hsTemp.label heat sink temperature (C)"
|
||||
print "hsTemp.max 120"
|
||||
print "hsTemp.warning :60"
|
||||
print "hsTemp.critical :80"
|
||||
print "battTemp.label battery temperature (C)"
|
||||
print "battTemp.max 120"
|
||||
print "aPanel.label panel current (A)"
|
||||
print "aPanel.max 20"
|
||||
print "aPanel.warning :15"
|
||||
print "aPanel.critical :19"
|
||||
print "aBatt.label battery current (A)"
|
||||
print "aBatt.max 20"
|
||||
print "aBatt.warning :15"
|
||||
print "aBatt.critical :19"
|
||||
exit(0)
|
||||
# import the server implementation
|
||||
from pymodbus.client.sync import ModbusTcpClient as ModbusClient
|
||||
|
||||
# configure the client logging
|
||||
import logging
|
||||
logging.basicConfig()
|
||||
log = logging.getLogger('./modbus.error')
|
||||
log.setLevel(logging.ERROR)
|
||||
|
||||
client = ModbusClient(host,502)
|
||||
client.connect()
|
||||
|
||||
# Define the State list
|
||||
state = ['Start', 'Night Check', 'Disconnected', 'Night', 'Fault!', 'MPPT', 'Absorption', 'FloatCharge', 'Equalizing', 'Slave']
|
||||
|
||||
# read registers. Start at 0 for convenience
|
||||
rr = client.read_holding_registers(0,80,1)
|
||||
|
||||
# for all indexes, subtract 1 from what's in the manual
|
||||
V_PU_hi = rr.registers[0]
|
||||
V_PU_lo = rr.registers[1]
|
||||
I_PU_hi = rr.registers[2]
|
||||
I_PU_lo = rr.registers[3]
|
||||
|
||||
V_PU = float(V_PU_hi) + float(V_PU_lo)
|
||||
I_PU = float(I_PU_hi) + float(I_PU_lo)
|
||||
|
||||
v_scale = V_PU * 2**(-15)
|
||||
i_scale = I_PU * 2**(-15)
|
||||
p_scale = V_PU * I_PU * 2**(-17)
|
||||
|
||||
# battery sense voltage, filtered
|
||||
battsV = rr.registers[24] * v_scale
|
||||
battsSensedV = rr.registers[26] * v_scale
|
||||
battsI = rr.registers[28] * i_scale
|
||||
arrayV = rr.registers[27] * v_scale
|
||||
arrayI = rr.registers[29] * i_scale
|
||||
statenum = rr.registers[50]
|
||||
hsTemp = rr.registers[35]
|
||||
rtsTemp = rr.registers[36]
|
||||
outPower = rr.registers[58] * p_scale
|
||||
inPower = rr.registers[59] * p_scale
|
||||
minVb_daily = rr.registers[64] * v_scale
|
||||
maxVb_daily = rr.registers[65] * v_scale
|
||||
minTb_daily = rr.registers[71]
|
||||
maxTb_daily = rr.registers[72]
|
||||
dipswitches = bin(rr.registers[48])[::-1][:-2].zfill(8)
|
||||
led_state = rr.registers
|
||||
print "vBattTerm.value %.2f" % battsV
|
||||
print "vBattSense.value %.2f" % battsSensedV
|
||||
print "aBatt.value %.2f" % battsI
|
||||
#print "battery watts: %.2f" % (battsV*battsI)
|
||||
print "vPanel.value %.2f" % arrayV
|
||||
print "aPanel.value %.2f" % arrayI
|
||||
#print "array watts: %.2f" % (arrayV*arrayI)
|
||||
print "hsTemp.value %.2f" % hsTemp
|
||||
print "battTemp.value %.2f" % rtsTemp
|
||||
#print "state: %s" % state[statenum]
|
||||
#print "out power: %0.2f" % outPower
|
||||
#print "in Power: %0.2f" % inPower
|
||||
#print "min Vb daily: %0.2f" % minVb_daily
|
||||
#print "max Vb daily: %0.2f" % maxVb_daily
|
||||
#print "min Tb daily: %0.2f" % minTb_daily
|
||||
#print "max Tb daily: %0.2f" % maxTb_daily
|
||||
#print "dipswitches: %s" % dipswitches
|
||||
#print "dipswitches: 12345678"
|
||||
#print ""
|
||||
client.close()
|
||||
|